Secondary fluids - GLYCOLS GK Lab?
Solvents and flushing fluids for Refrigeration & Air Conditioning piping GK Lab?
Leak detectors & Dye - GK Lab? for Refrigeration, Air Conditioning Auto A/C
Gas Leak Stop for Refrigerant Leakages GK Lab?
Additives for PH Value, Moisture, Deposits of Oil and Refrigerant Gas Leak - GK Lab?
Disinfectants and sanitizers with Bactericide and Virucidal Efficacy - Medical Devices
Auto - DPF Cleaning - Diesel Particulate Filters
Leak Stopper for Vehicles Cooling System
Chemical Products
HVACR tools - Flaring tools and flare lubricant
HVACR tools - Tube cutters and deburrers
Electronic Leak Detectors (infrared and heated diode), foaming detectors
Recovery Units for A1, A2L and A3 refrigerants (R290 propane)
Nitrogen and Nitrogen/Hydrogen Pressure Kit + Testers for Refrigeration and A/C systems
High vacuum pumps and hoses for HVACR systems
Digital Manifold Gauges, vacuum meters and bluetooth probes for pressure, temperature, humidity
Refrigerant digital weighing scales
Electronic Instrumentation for Diagnosis of Refrigeration & A/C systems
HVACR tool backpacks (original Fieldpiece)
Charging and recovery hoses for refrigerants
Refrigeration oil charging pump for HVACR systems
Washing and cleaning units for Refrigeration & Air Conditioning systems
Adapters, connectors, depressors, shut-off, filters, valves GK Tools?
Sensors and control units for detecting leaks of refrigerant gases in the environment
T-PED Refrigerant cylinders (refillable)
Quick Couplers and Adapters - Automotive
N2, O2, C2H2 high pressure cylinders
G-TEC small cylinders (argon, CO2, blend Ar/CO2) and pressure gauges
Calibration and Check Service for F-Gas Instruments and Tools
Equipment
You can recover your password by entering the email you registered with and clicking on "RECOVER PASSWORD".
Total
$ 0.00
SAMON GXR230-HFC: ATEX detection unit with remote sensor, for synthetic refrigerants A2L (HFO and HFC included R32) - unit with relay output and semiconductor sensor (SC)
Do you need to buy large quantities?
(HFC and HFO in flammability class A2L, including R32) – Detectors for synthetic refrigerants G-series
SAMON code: 37-725
Sensors for installation in engine rooms, compressor rooms and any other application where gases are used or stored
Control unit for installation in a safe area
Sensor for installation in hazardous areas
Certificate Atex Exd IIB + H2 T6/3* Range T6 = - 40 / + 40°C
Features:
The microprocessor unit displays, through multicolorED LEDs, the operation of the control unit itself
Three operator-adjustable alarm levels with relay output (230V / 5A)
Alarm delay time (4 levels) can be set
Manual or automatic alarm reset
Built-in "Fail-safe" and "Power failure alarm" function
Integrated self-diagnosis
Diagnostic terminals
Robust, anti-corrosion housing for installation in industrial environments
Technical specifications:
0-4000 ppm
Power supply 230V approx, max 2 W
Waterproof housing, installation in the environment
Atex remote sensor, certified for explosion risk zone, equipped with 5 meters of cable
Ambient temperature: control unit from -40°C to +50°C, remote sensor from -40°C to +40°C
Humidity: 0 . 95% Rh (non-condensing)
IP56 protection
Factory standard alarm set (levels gained from experience):
Sensor Type: HFC
Measuring range (ppm): 0 - 4000
Alarm levels (ppm) 100 / 1000 / 2000
Alarms for HFC sensors are set to R134 but indicate all HCFCs, CFCs and HFOs with a slight difference in alarm intervention
Customized settings are possible, contact us for information
NOTE: Sensors are consumable parts Estimated life: 5 years Very simple sensor replacement Calibration method: DT300 Maintenance: Annual
EAN | n.d. |
Package weight | 3 Kg. |
Item number | F-AF-SC-SAM-GXR230B |
Packaging | Cardboard box |
Data sheet | Signup or Signin for Download |
Instruction manual | Signup or Signin for Download |
SAMON GS230-HFC: detection unit with built-in sensor, for synthetic refrigerants A1 and A2L (HFC including R32 and HFO) - unit with relay output and semiconductor sensor (SC)
SAMON GSR230-HFC: detection unit with remote sensor, for synthetic refrigerants A1 and A2L (HFC including R32 and HFO) - unit with relay output and semiconductor sensor (SC)
SAMON GXR230-HC: ATEX detection unit with remote sensor, for propane R290 and HC - unit with relay output and semiconductor sensor (SC)
SAMON GSLS230-CO2-10000: detection unit with built-in sensor and light + acoustic alarm, for carbon dioxide CO2 (R744) - unit with relay output and IR sensor (NDIR)
SAMON MPU4C: MPU control unit - 4-channel multi-zone control unit with light + acoustic alarm (for HFC, HFO and CO2) - unit with relay output, connectable to external sensors (supplied separately)
SAMON MP-DS (HFC/HFO/R32) – Detector for synthetic refrigerants for connection to MPU control panel - semiconductor sensor (SC)
SAMON MPS (CO2) – Carbon dioxide CO2 detector (R744) for connection to MPU control panel - IR sensor (NDIR)
SAMON GEX (R290 and HC) – Detector for R290 and hydrocarbons, for connection to MPU power plant - semiconductor sensor (SC)