Secondary fluids - GLYCOLS GK Lab?
Solvents and flushing fluids for Refrigeration & Air Conditioning piping GK Lab?
Leak detectors & Dye - GK Lab? for Refrigeration, Air Conditioning Auto A/C
Gas Leak Stop for Refrigerant Leakages GK Lab?
Additives for PH Value, Moisture, Deposits of Oil and Refrigerant Gas Leak - GK Lab?
Disinfectants and sanitizers with Bactericide and Virucidal Efficacy - Medical Devices
Auto - DPF Cleaning - Diesel Particulate Filters
Leak Stopper for Vehicles Cooling System
Chemical Products
HVACR tools - Flaring tools and flare lubricant
HVACR tools - Tube cutters and deburrers
Electronic Leak Detectors (infrared and heated diode), foaming detectors
Recovery Units for A1, A2L and A3 refrigerants (R290 propane)
Nitrogen and Nitrogen/Hydrogen Pressure Kit + Testers for Refrigeration and A/C systems
Digital Manifold Gauges, vacuum meters and bluetooth probes for pressure, temperature, humidity
Refrigerant digital weighing scales
Electronic Instrumentation for Diagnosis of Refrigeration & A/C systems
HVACR tool backpacks (original Fieldpiece)
Charging and recovery hoses for refrigerants
Refrigeration oil charging pump for HVACR systems
Washing and cleaning units for Refrigeration & Air Conditioning systems
Adapters, connectors, depressors, shut-off, filters, valves GK Tools?
Sensors and control units for detecting leaks of refrigerant gases in the environment
T-PED Refrigerant cylinders (refillable)
Quick Couplers and Adapters - Automotive
N2, O2, C2H2 high pressure cylinders
G-TEC small cylinders (argon, CO2, blend Ar/CO2) and pressure gauges
Floor supports for R&AC outdoor units
Calibration and Check Service for F-Gas Instruments and Tools
Equipment
You can recover your password by entering the email you registered with and clicking on "RECOVER PASSWORD".
Total
$ 0.00
20 x Complete Treatment Kit (no Adapters) AC/R RESTORING TREATMENT (KIT ULTRA) - 4 Cartridges in Clamshell packaging - Package # 20 pcs
Do you need to buy large quantities?
Chemical Eco-Friendly Solutions for Air Conditioning and Refrigeration Systems
Any contractors working in the maintenance of Air Conditioning & Refrigeration Systems often deal with the problem of refrigerant gas leaks without analyzing the reason why they occur.
First of all it must be explained that in any Air Conditioning or Refrigeration system the compressor, which is lubricated by a specific oil, compresses a refrigerant gas which overheats when exposed to this action.
The overheated refrigerant gas passes inside a condenser which cools it partially and transforms it into a refrigerant in liquid state, then a dry filter subtracts the moisture contained in it.
The refrigerant now passes through a valve that makes it expand inside an evaporator turning it again into a very cold refrigerant gas in a gaseous state due to the expansion effect.
During these processes different chemical reactions occur, the refrigerant gas and the oil tend to decompose, releasing moisture and acids of a halogen and organic nature.
After many hours of working the system, the dry filter becomes saturated and the humidity begins to circulate freely in the system and combines with the fluorine contained in the refrigerant gas, producing acidity that irreversibly compromises many of the system parts and leading to a slow but constant corrosion of the system components, with a consequent and inevitable loss of refrigerant gas and the potential burn of the compressor above all.
Refrigerant gas leaks cause a decrease in the working pressure of the system, with consequent greater stress on the system and an inevitable loss of performances.
In addition, a percentage between 8% and 15% of the volume of the oil in the compressor is dragged by the refrigerant gas throughout the system and over time will tend to settle (“oil-fouling”) and accumulate especially inside the condenser and the evaporator, lowering the correct level of oil in the compressor and so compromising the performance of the whole system (it will provide less cold and/or less hot air).
In our laboratories we have developed a procedure composed of 4 specific additives that, used in a precise sequence, eliminate the consequences of these actions/reactions, preserving the Air Conditioning & Refrigeration System from all the problems inherent to refrigerant gas leaks and the decrease of performance.
STEP #1 consists in the insertion, with the system on, of the first additive called No-Acid Ultra, whose aim is to restore the correct Ph value of the oil.
STEP #2 After waiting at least 5 minutes after inserting No-Acid Ultra, a second additive called Super Dry Ultra must be inserted. This additive aims to eliminate all the moisture circulating in the system by incorporating inside its molecules the molecules of water that are not retained by the dry filter already saturated by the moisture.
STEP #3 After waiting for another 6 minutes, you can insert the third additive called Cool Shot Ultra, which aims to remove all the deposits of oil that have accumulated in the system, especially inside the condenser and the evaporator, that will rejoin the oil which already contains No Acid Ultra and Super Dry Ultra. At this point we will have completely detached all the oil residues inside the system and have restored the correct oil level inside the compressor.
STEP #4 After waiting at least 20 minutes, we can proceed with the insertion of the fourth additive Extreme Ultra. This additive will repair all the refrigerant gas microleaks that had been caused by acids that were formed in the oil.
EAN | 8033158041047 |
Cylinder/Container size | 6 ml |
Packaging Overall Dimensions | 590 x 195 x H265 mm. |
Package weight | 3 Kg. |
Product Type | Ready |
Implementing rules: | Ready to use |
Suitable For: | Internal conditioners split units |
External Split Unit Air Conditioners | |
Fan coil air conditioning | |
Capacitors conditioning chillers | |
Refrigeration - Evaporators | |
Refrigeration - Condensers | |
A/C and Refrigeration Units | |
Cleaning of Oil and Grease | |
Dirty Cleaning-off | |
Leaks Repairing | |
Enhancing energetic performance of R&AC systems | |
Dehydrating R&AC systems | |
Neutralizing Acids | |
Item number | F-ER-PC-KIT-01 |
Packaging | Blister pack |
Data sheet | Signup or Signin for Download |
Material Safety Data Sheet | Signup or Signin for Download |
20 x Complete Treatment Kit AC/R RESTORING TREATMENT (KIT ULTRA) - 4 Cartridges in Clamshell packaging + 1/4 SAE and 5/16 SAE adapters + flexible adapter - packages # 20 pieces
30 x Performance Enhancer (supplied with no adapters) - COOL SHOT ULTRA - Cartridge 6 ml - Package # 30 pcs
30 x Performance Enhancer (with adapters 1/4 SAE + 5/16 SAE + flexible hose) - COOL SHOT ULTRA - Cartridge 6 ml - Package # 30 pcs
30 x Dehydrating Additive (supplied with no adapters) - SUPER DRY ULTRA - Cartridge 6 ml - Package # 30 pcs
30 x Dehydrating Additive + adapters 1/4 SAE and 5/16 SAE + Flexible Adapter - SUPER DRY ULTRA - Cartridge 6 ml - Package # 30 pcs
30 x Acid Neutralizer (supplied with no adapters) - NO ACID ULTRA - Cartridge 6 ml - Package # 30 pcs
30 x Acid Neutralizer + adapters 1/4 SAE and 5/16 + flexible hose - NO ACID ULTRA - Cartridge 6 ml - Package # 30 pcs
30 x Plastic Adapters R&AC Kit for Syringes ULTRA System and Dyes - 1/4 and 5/16 SAE + Flex Adapter - Package # 30 Kit
20 x Plastic Adapter Kit for Syringes ULTRA System and Dyes - 1/4 SAE - Package # 20 Pcs.
20 x Plastic Adapter R&AC Kit for Syringes ULTRA System and Dyes (R&AC) - 5/16 SAE - Package # 20 Pcs.
30 x Plastic Adapters AUTO Kit for Syringes ULTRA System and Dyes - R134a and HFO 1234yf + Flex Adapter - Package # 30 Kit
50 x Flexible Hose R&AC and AUTO for Syringes ULTRA System and Dyes - Package # 20 Pcs.